Wega Espresso Coffee Machine Service Manual Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
English
CNS
9
espresso coffee machine - servings count
R
9. SERIAL CONNECTION
The system is able to interface in serial mode with the coffee machine.
Refer to the technical specifications for dosing for their correct configuration.
Connection is made by means of an RS232 serial line, with the appropriate cable.
Serial transmission characteristics:
BAUD RATE 1200 bit/sec
DATA LENGTH 8 bit
PARITY EVEN
STOP BIT 2
CLOCK RATE 64
VOLTAGE LEVELS 0/+5 Vdc
Operation
A code corresponds to each dosing key. When a serving is requested from a certain key, the dosing device sends the relative code by means
of its serial line. If it receives in reply the same code or a code from 1 to 15 (decimal) the serving is delivered, otherwise it is deleted. The
codes are typical of the traditional interface with the Gicar Stroke Count, which transmits a code that makes it possible to recognize the
staff that is using the machine (1...13 : waiters, 14 : manager, 15 : owner).
List of codes used by dosing:
11H Group 1 Key 1
12H Group 1 Key 2
13H Group 1 Key 3
14H Group 1 Key 4
15H Group 1 Key Tea 1
16H Group 1 Key Tea 2
17H Group 1 Stop/Cont/Prog Key (Dosmask series)
19H Group 1 Stop/Cont/Prog Key (Dosmask series)
21H Group 2 Key 1
22H Group 2 Key 2
23H Group 2 Key 3
24H Group 2 Key 4
25H Group 2 Key available
26H Group 2 Key available
27H Group 2 Stop/Cont/Prog Key (Dosmask series)
29H Group 2 Stop/Cont/Prog Key (Dosmask series)
31H Group 3 Key 1
32H Group 3 Key 2
33H Group 3 Key 3
34H Group 3 Key 4
35H Group 3 Key available
36H Group 3 Key available
37H Group 3 Stop/Cont/Prog Key (Dosmask series)
39H Group 3 Stop/Cont/Prog Key (Dosmask series)
41H Group 4 Key 1
42H Group 4 Key 2
43H Group 4 Key 3
44H Group 4 Key 4
45H Group 4 Key available
46H Group 4 Key available
47H Group 4 Stop/Cont/Prog Key (Dosmask series)
49H Group 4 Stop/Cont/Prog Key (Dosmask series)
The system replies code 15 (decimal), thus enabling delivery of the serving (even if the activation key is inserted).
During any data reading or deletion operation, the system does not reply or replies with a code which is not recognized by the dosing. In this
case, delivery is not performed and the serving is not counted.